Sign In | Join Free | My burrillandco.com
Home > Residual Current Device >

VKL11 Certified NF Residual Current Device Type EV Rcd

    Buy cheap VKL11 Certified NF Residual Current Device Type EV Rcd from wholesalers
     
    Buy cheap VKL11 Certified NF Residual Current Device Type EV Rcd from wholesalers
    • Buy cheap VKL11 Certified NF Residual Current Device Type EV Rcd from wholesalers
    • Buy cheap VKL11 Certified NF Residual Current Device Type EV Rcd from wholesalers
    • Buy cheap VKL11 Certified NF Residual Current Device Type EV Rcd from wholesalers

    VKL11 Certified NF Residual Current Device Type EV Rcd

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Certified NF Residual Current Device Type EV Rcd

    VKL11 Residual Current Device (RCD) type EV


    1. General

    1.1 Function

    Residual Current Device VKL11 TYPE A EV (RCD TYPE A EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and IEC62955(RDC-PD:Residual Direct Current Protective Device )

    VKL11 Type A EV RDC-PD/RCD is designed specifically for use in Mode 3 charging applications.

    1.2 Selection

    Detectable wave form AC class

    Tripping is ensured for slowly increasing sinusoidal AC

    residual currents

    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

    Smooth DC 6mA

    smooth DC residual currents (switch-off at max 6 mA)


    1.3 Approvals and certificates :UKCA,CE


    Tripping sensitivity

    30mA - 50Hz sinusoidal AC ; Pulsating DC

    Smooth DC ≥ 6 mA (RDC-PD)

    Tripping time

    Instantaneous

    It ensures instantaneous tripping(without time-delay).



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1,IEC 62955
    Electrical featuresModel No.VKL11 A EV
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A-40A), 30mA, 100mA, 300mA
    DC tripping threshold6mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui500V
    Rated frequency50/60 Hz

    Rated residual making and

    breaking capacity I△m

    500A (In=16A, 25A, 32A, 40A)
    630A(In=63A), 800A(In=80A), 1000A(In=100A)
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)

    AC, A

    Smooth DC 6mA

    Tripping timeInstantaneous
    break time under I△n

    ≤100ms

    (Normal type)

    Rated impulse withstand voltage(1.2/50) Uimp6kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 55℃
    Storage temperature-40℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom
    StandardEN61008-1 ,IEC62955



    3. Outline and installation dimensions (mm)

    Product Description:

    A Residual Current Device (RCD) Inmetro 500V is a protective device designed to quickly disconnect the electrical circuit when a fault current is detected. This device is rated to a voltage of 500V and a frequency of 50/60Hz, with a rated residual operating time of 0.1s and a rated voltage of 240/415V AC. It is also rated to a protection class of IP20. This device is essential for the safety of your electrical system, and can help prevent serious injury or even death due to electrical shock.

    The RCD Inmetro 500V is a reliable and robust safety device, designed with advanced technology to protect against electrical shocks and fires. It offers a wide range of features, including a high level of electrical insulation, superior short-circuit protection, and overload protection. It has been tested and certified by Inmetro to meet the highest safety standards, and is suitable for both commercial and residential applications.

    The RCD Inmetro 500V is an essential device for protecting both people and property, and is an important part of any electrical system. It is easy to install and maintain, and can provide peace of mind that your electrical system is well protected. So if you're looking for reliable electrical safety, the RCD Inmetro 500V is the perfect solution.

    Features:

    • Product Name: Residual Current Device
    • Type: Type EV
    • Rated Impact Endurance Voltage: 2kV
    • Rated Frequency: 50/60Hz
    • Rated Impulse Withstand Voltage: 4kV
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

    Applications:

    HAROK VKL11 Residual Current Device (RCD) is designed to protect people from electric shock and provide an extra layer of safety in electrical circuits. It detects and quickly breaks an electrical circuit when a leakage of current is detected, which helps to prevent electric shock, fire and other hazards. This RCD meets the latest UL1053 standard and is certified to NF, SEMKO, VDE, KEMA, ISI and CE standards. It has a rated impact endurance voltage of 2kV, a rated residual operating current of 30mA, a rated voltage of 240/415V AC, a rated residual operating time of 0.1s, and a rated short-circuit capacity of 10KA. It is perfect for indoor use in residential, commercial and industrial settings. Our RCD is available in minimum orders of 1000 pieces and comes in a paper carton for easy storage and transport. We can supply up to 100,000 pieces per month with delivery within 4-6 weeks of payment.

    Technical Parameters:

    Parameter NameParameter Value
    Product NameResidual Current Device
    Rated Short-Circuit Capacity10kA
    Rated Voltage240/415V AC
    Rated Current16A-100A
    Rated Impulse Withstand Voltage4kV
    Rated Operating Temperature-25℃~+40℃
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA
    Rated Insulation Voltage500V
    Residual Current Device TypeTYPE A EV

    Customization:

    Residual Current Device with Type A EV

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE

    Minimum Order Quantity: 1000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Supply Ability: 100,000 PCS PER MONTH

    Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

    Rated Voltage: 240/415V AC

    Rated Frequency: 50/60Hz

    Rated Humidity: ≤95%RH

    Rated Residual Operating Current: 30mA-300mA

    Features:

    Residual Current Device Type A EV

    Packing and Shipping:

    Packaging and Shipping of Residual Current Device

    We use high-quality materials to package and ship the residual current device. Our package is strong and secure to ensure that the product reaches the destination in perfect condition.

    Packaging
    • The residual current device is placed in a strong cardboard box.
    • The box is filled with foam to provide extra protection.
    • The box is sealed with tape to ensure that it is secure.
    Shipping
    • The package is shipped via a reputable shipping company.
    • The package is tracked to ensure that it is delivered safely and on time.
    • Delivery is insured to ensure that the customer is covered in the event of any damage or loss.
    Quality VKL11 Certified NF Residual Current Device Type EV Rcd for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)