    50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VFL001
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

    VFL001 Rated 6kA Service Short-Circuit Breaking Capacity Residual Current Circuit Breaker (RCCB)


    VFL001 Residual Current Circuit Breaker(RCCB) Type A Type AC Type ASi


    1. General


    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.


    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity

    10mA - precision instrument leakage protection and bathroom use.

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

    300mA/500mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous

    It ensures instantaneous tripping(without time-delay).

    Short time delay ASi

    (High Immunity/ Avoid nuisance tripping &blinding)

    It ensures any tripping at least 10ms.

    Selective

    It ensures total discrimination with a non selective RCD placed downstream.

    50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater


    RCCB | Residual Current Circuit Breaker


    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VFL001
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom

    3. Outline and installation dimensions (mm)


    50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

    Product Description:

    Residual Current Circuit Breaker type A, type AC, type ASi is a reliable and safe product with a wide range of applications. It is designed to provide protection against electric shock due to leakage currents, as well as to detect short circuits and overloads. The RCCB has a rated voltage of 230V AC, and a rated current of 30mA-100mA. It is certified to meet the highest safety standards, including CE, ISI, NF, SEMKO, VDE, and KEMA. The RCCB with ISI mark has been tested and approved by the Indian Standard Institute, and the Residual Current Circuit Breaker Inmetro is certified by the Brazilian National Institute of Metrology, Quality, and Technology. The Residual Current Circuit Breaker with CE mark is compliant with the European Union's safety regulations. It has a rated operating duration of ≤1s and a rated operating frequency of 50/60Hz, providing superior protection against electric shock.

    Features:

    • Product Name: Residual Current Circuit Breaker RCCB
    • Certifications: NF SEMKO VDE KEMA, Residual Current Circuit Breaker with ISI mark
    • Rated Residual Operating Current: 10mA-300mA
    • Rated Service Impulse Withstand Voltage: 6kV
    • Rated Service Short-Circuit Breaking Capacity: 10kA
    • Rated Residual Current Off-Time: ≤0.1s
    • Rated Current: 16A-100A

    Applications:

    HAROK VFL001 Residual Current Circuit Breaker RCCB with Inmetro certification is an ideal device for protecting people from electric shock and fire risks, as it can detect and isolate the fault current immediately with its rated current 30mA-100mA and insulation voltage 500V. It is certified by NF, SEMKO, VDE, KEMA, ISI, CE and has a rated service impulse withstand voltage of 6kV, rated short-circuit breaking capacity of 10kA, which makes it suitable for different applications. With a minimum order quantity of 5000 pieces, the product can be delivered in 4-6 weeks after payment, and the paper carton packaging ensures the safety of the products. With the ability to produce 100,000 pieces per month, HAROK VFL001 Residual Current Circuit Breaker RCCB is the perfect choice for any residential, commercial and industrial applications.

    Technical Parameters:

    ParameterValue
    Rated Short-Circuit Breaking Capacity10kA
    Rated Service Short-Circuit Breaking Capacity10kA
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA
    Rated Residual Current Off-Time≤0.1s
    Rated Insulation Voltage500V
    Rated Ultimate Short-Circuit Breaking Capacity10kA
    Rated Residual Operating Current30mA-300mA
    Rated Voltage240/415V AC
    Rated Frequency50/60Hz

    Customization:

    Residual Current Circuit Breaker RCCB with ISI Mark
    • Brand Name: HAROK
    • Model Number: VFL001
    • Place of Origin: CHINA
    • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
    • Minimum Order Quantity: 5000
    • Packaging Details: PAPER CARTON
    • Delivery Time: 4-6 weeks after payment
    • Payment Terms: FOB NINGBO or SHANGHAI
    • Supply Ability: 100,000 PCS PER MONTH
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
    • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
    • Rated Voltage: 240/415V AC
    • Rated Impulse Withstand Voltage: 4kV
    • Rated Current: 30mA-300mA

    Packing and Shipping:

    Packaging and Shipping of Residual Current Circuit Breaker RCCB

    Residual Current Circuit Breaker RCCB is usually packaged in a single box that contains the breaker, instruction manual, and all necessary accessories. The box is then wrapped in a plastic bag for protection against moisture and dust.

    The package should also include a packing slip with the order number, delivery address, product information, and any other pertinent information.

    The package should be labeled with the product name, item number, customer name, and any other relevant information.

    The package should be securely packaged for shipping. The box should be sealed using tape and should be clearly labeled with the shipper's address and any other relevant information.

    Shipping should be done using a reliable carrier service. The package should be insured to ensure the safety of the product during transit. Tracking information should be provided to the customer so they can follow the package's progress.

    Quality 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)